I am excited about biWaze because the device will provide a more comfortable and effective therapy so
patients will be more adherent to what we prescribe.
The BiWaze® Cough System from ABM Respiratory Care changes that dynamic with dual air pathways separated for inhale and exhale flows. This helps ensure the inhaled air is not contaminated with mucus from the exhaled air.
It only makes sense. And it’s only from ABM Respiratory Care.
BiWaze Cough is the respiratory therapy system that combines multiple therapies of assisted cough and lung expansion along with high frequency oscillation, BiWaze Cough breaks up and then removes mucus from the lungs by applying positive air pressure (inhale) to the airway and then rapidly shifting to negative air pressure (exhale).
After exhale, the pause phase allows the user to rest before the next assisted cough cycle. BiWaze Cough can provide positive pressure flow during the pause phase so the person’s airways are stinted open after the exhale instead of being forcefully reopened with the next inhale.
BiWaze Cough was inspired by people who need airway clearance treatments tailored to their changing respiratory needs. The dual airpath control separates the inhale and exhale air flow to help ensure the inhaled air is not contaminated with mucus from the exhaled air. The low profile design and simplified touch screen navigation make BiWaze Cough easy to use. The system provides a non-invasive solution to enhance airway clearance is essential to avoid retained mucus that causes infection, inflammation, and respiratory failure. Each therapy cycle can be personalized to provide the most effective therapy for a person’s respiratory condition.
It is designed to provide cleaner care, easier implementation and, is a smarter solution. To put it simply, BiWaze Cough is a breath of fresh care.
Operating temperature | 40° to 95°F (5C to 35C) |
Relative humidity | 15 to 95% (non condensing) |
Size | 27 cm L x 23.5 cm W x 9.0 cm H (10.5″ L x 9.2″ W x 3.5″ H) |
Weight | 9lbs (4kg) including internal battery |
Presets | Up to 10 |
Modes | Automatic and Manual |
Maximum positive pressure | 70 cm H20 |
Maximum negative pressure | -70 cm H20 |
Maximum pause pressure | 15 cm H20 |
Inspiratory time | 0 – 5 seconds (auto mode only) |
Expiratory Time | 0 – 5 seconds (auto mode only) |
Pause Time | 0 – 5 seconds (auto mode only) |
Inspiratory Flow | Low, Medium, High |
Inspiratory trigger sensitivity | 1 – 10 |
Oscillation frequency | 5 – 20 Hz |
Amplitude | 1 – 5 |
Oscillations
The oscillation therapy feature delivers an oscillatory therapy based on frequency and amplitude settings. Use of the oscillation feature enhances mobilization and improves bronchial drainage.
Inspiratory Trigger
An important characteristic of the system is its ability to trigger on the patient’s inhale to help synchronize the therapy with the patient. The inspiratory trigger feature is available when the device is in Auto mode. The pressure delivery sequence is synchronized with the patient’s effort to inhale.
Inspiratory Flow
While the expiratory switching is desired to be fast and at high flow to simulate cough, the inspiratory flow may be controlled to a comfortable level by
selecting the flow between low, medium and high.
Positive Airway Pressure on the Pause Phase
Provides the option to keep airways open in-between the exhalation and inhalation phases of the cycle cough. This feature is designed to make the therapy more comfortable for the patient.
ABM Respiratory Care will advance the healthcare industry by developing intelligent, clinically differentiated and innovative respiratory care solutions to help people breathe better inside and outside the hospital.