Breathing new life into traditional therapy™
BiWaze® Cough clears mucus from the lungs by applying positive air pressure to the airway, then rapidly shifting to negative pressure — an assisted cough engineered around respiratory physiology, with the precision control hospital care teams need at the bedside.
Airway hygiene is a two-system job
Mucociliary clearance provides continuous housekeeping in the conducting airways. The cough reflex is the rapid-flow, high-shear backup that clears what mucociliary clearance can't — especially from the larger, central airways.
When coughing becomes difficult
Muscle weakness or loss of diaphragm control can make the cough reflex ineffective. When that happens, manual or mechanical assisted cough therapy may be prescribed.
Mechanical assist (MI-E): a cough assist device gently blows air into the lungs, then quickly pulls it out. One "in-and-out" is a cough cycle; a typical therapy uses 4–6 cycles in a row.
Assisted cough therapy can make breathing easier and help patients feel more comfortable day to day.
Where BiWaze® Cough is used in the hospital
Critical & emergency care
- Emergency Department
- Trauma
- Intensive Care Units
Inpatient & recovery
- Medical / Surgical Units
- Rehabilitation Areas
- Long-Term Ventilation and Weaning Units
The evidence for MI-E at extubation
In a randomized controlled trial, adding MI-E to the extubation protocol was associated with improved post-extubation outcomes compared with standard care.
Gonçalves MR, Honrado T, Winck JC, Paiva JA. Effects of mechanical insufflation-exsufflation in preventing respiratory failure after extubation: a randomized controlled trial. Crit Care. 2012;16(2):R48. — Published study of MI-E therapy; not a BiWaze-specific clinical trial.
The assisted cough cycle
A cough cycle is pause, inhale, exhale — delivered in sequences of 3–6 cycles, with rest between sets.
¹ Malone P, DiBlasi R. BiWaze® Cough System – A bench study evaluation and comparison of cough efficiency (Rev. 2.0). ABM Respiratory Care; 2022.
A typical therapy plan
MI-E therapy is typically titrated to the individual — starting low and increasing as tolerated.
3–6 cough cycles
Delivered in rapid succession. One cough cycle = pause + inhale + exhale.
20–30 seconds
Between sets, let the patient rest and clear secretions visible in the mouth, throat, or tracheostomy tube.
3–6 times
Repeat the sequence, or until secretions are sufficiently expelled.
Start low, go slow
Begin with lower pressures (e.g., +10–15 / −15 cm H₂O) and increase as tolerated. Set oscillations to patient comfort.
Hygienic. Intelligent. Intuitive.
A dual-blower design, engineered to mimic the natural way a body coughs.
Hygienic
- Dual-blowers independently generate positive and negative airflow — separating exhaled mucus from inhaled air
- Optional dual-lumen circuit further separates exhaled mucus and bacteria from fresh inhaled air
- Disposable breathing circuit designed for single-patient use
Intelligent
- Software algorithms dynamically control blowers and integrated valves; each pathway has sensors measuring pressure and flow
- CoughCue lets the device synchronize with the patient's own effort — slow deep inspiration, optional hold, then expiratory phase — rather than forcing a preset timing
- Programmable high-frequency oscillations delivered consistently through the entire cough cycle¹
- Arc Connect™ app with Remote Control, live waveforms, and shareable reports
Intuitive
- 7″ touchscreen with simplified therapy screen and auto/manual modes
- Up to 10 stored therapy profiles and up to 20 cycles per therapy
- Manual-mode titration feedback (thumbs up/down after each cycle) to support comfort-driven settings
- Slim, modern design with a lock screen to prevent unintended touches
¹ Malone P, DiBlasi R. BiWaze® Cough System – A bench study evaluation and comparison of cough efficiency (Rev. 2.0). ABM Respiratory Care; 2022.
Therapy tracking and remote visibility
Arc Connect adds a digital support layer for compatible BiWaze Cough systems — from live waveforms during therapy to post-session insights.
Remote Control + live waveforms
- View live flow, pressure, and volume curves as therapy is delivered
- Start or pause therapy from the app when Remote Control is connected
- Toggle individual curves and adjust scale/zoom to focus on session detail
Post-session insights
- Review waveform patterns from completed sessions
- See therapy timing, cycle counts, and adherence information
- Reference therapy settings and titration feedback
Tracking + sharing
- Track therapy activity and adherence over time
- Downloadable reports and trend insights
- Permission-based sharing of patient-level data with care teams
Requires compatible BiWaze Cough software v1.23.0+ and Arc Connect on iOS 16.0+ or Android 9.0+. Remote Control/live waveforms use Bluetooth; therapy data sync requires Wi-Fi. Guest access is available for Remote Control/live waveform use; account setup is required for saved tracking and sharing features.
The system, ready for the unit
A control unit with a 7″ touchscreen, single-patient circuit options, and mobility choices for each care setting.
In the hospital
BiWaze Cough mounts on a mobile cart with an integrated basket, so therapy moves easily between rooms and care units.
For home care, the same system travels in a padded carrying bag — one therapy platform across settings.
Two circuit options, one simple assembly — each circuit is single-patient use.
Single-lumen circuit assembly
Step-by-step assembly, from control unit to patient interface.
Coaxial dual-lumen circuit assembly
The dual-lumen option separates exhaled mucus and bacteria from fresh inhaled air.
Explore the clinical research — and the coding path.
BiWaze® Cough — Cough Efficiency Bench Study
In-vitro evaluation of cough efficiency conducted by Seattle Children's Hospital and Research Institute: BiWaze Cough delivers a consistent, square-shaped inhalation flow pattern resembling natural pre-cough inspiration, with a distinctive expiratory flow interruption similar to glottic closure.¹
Read the white paper →Coding & coverage resources
BiWaze® Cough is assigned HCPCS code E0482 (cough stimulating device system), with A7020 for the breathing circuit. Our team supports hospital and home-care partners with coding education, documentation resources, and prescription forms.
¹ Malone P, DiBlasi R. BiWaze® Cough System – A bench study evaluation and comparison of cough efficiency (Rev. 2.0). ABM Respiratory Care; 2022.
The details, all in one place.
| Maximum positive pressure | 70 cm H₂O |
| Maximum negative pressure | −70 cm H₂O |
| Maximum pause pressure | 15 cm H₂O |
| Cough cycles | Up to 20 per therapy |
| Oscillation | Frequency 5–20 Hz · Amplitude 1–5 |
| Timing | Inspiratory, expiratory & pause time 0–5 seconds (auto mode) |
| Modes & presets | Automatic and Manual · up to 10 stored therapy profiles · inspiratory flow Low/Medium/High · trigger sensitivity 1–10 |
| Device | 27 × 23.5 × 9 cm (10.5″ × 9.2″ × 3.5″) · 9 lbs (4 kg) including internal battery · 7″ touchscreen |
| Battery | Built-in lithium-ion battery included — supports up to 2 hours of therapy (based on a new, fully charged battery) |
| Circuits | Single-lumen or coaxial dual-lumen breathing circuits, single-patient use · 30 days or 90 typical therapies, whichever comes first |
| Environment | Operating temperature 40–95°F (5–35°C) · relative humidity 15–95% non-condensing |
| Regulatory | FDA 510(k) K191912 · View the FDA clearance letter (PDF) → |
Downloads
Clinical evidence
Clinical tools
Bring BiWaze® Cough to your facility
Whether you’re ready to learn more, see BiWaze Cough in action, evaluate the system, or move forward with implementation, our team is here to help. Connect with us for a demonstration, clinical in-service, product evaluation, and staff training.
BiWaze Cough FAQ.
Automatic or manual delivery?
Both. Automatic mode cycles the inhale, exhale, and pause phases on preset timing; manual mode gives the clinician direct control of each cycle — with optional thumbs-up/down titration feedback after each cycle.
How many patient profiles can be stored?
Up to 10 personalized therapy profiles, with advanced programming to customize pressures, durations, oscillations, and cycles.
Can it run on battery?
Yes — the integrated lithium-ion battery supports up to 2 hours of therapy, and the system moves easily between rooms and care units. A cart is available for hospital use.
What's new in the latest software?
Compatible systems (software v1.23.0+) support CoughCue patient-synchronized triggering, titration feedback, and Arc Connect Remote Control with live flow, pressure, and volume waveforms.
How do we order for our facility?
Contact the ABM Respiratory Care team through our Contact & Support page or call 877-226-7201.
See it with your team.
A side-by-side evaluation — in your unit or online — beats any brochure. Schedule a demo and our team will set it up.